Matomo

Turbiti 636 pump skid specs

Specifications turbiti 636 nanobubble generator pump skid for water volumes of 200 to 300 liters / minute

Download Brochure
Turbiti 636 O2 nanobubble pumpskid generator for salt and seawater applications
Back to: Turbiti Skid
DescriptionMetricImperial
1 Model name Turbiti 636 pump skid Turbiti 636 pump skid
2 Model number turbiti_636_pumpskid_3p-230V_50Hz turbiti_636_pumpskid_3p-230V_50Hz
3 Technology Turbulent Mixer Ejector Turbulent Mixer Ejector
LiquidMetricImperial
4 Minimum flow / minute 83 Liter 22 Gallon
5 Maximum flow / minute 220 Liter 58 Gallon
6 Minimum flow / hour 5.0 M3 175.9 CF
7 Maximum flow / hour 13 M3 466 CF
8 Recommended inlet filter(s) Medium pump inlet filter series
Medium pump inlet filter series
AmbientMetricImperial
9 Ambient temperature minimum -20 ℃ -4 ℉
10 Ambient temperature maximum 35 ℃ 95 ℉
GasMetricImperial
11 Minimum flow / minute 5.0 Liter 1.3 Gallon
12 Maximum flow / minute 8.0 Liter 2.1 Gallon
13 Minimum flow / hour 300 Liter 79 Gallon
14 Maximum flow / hour 480 Liter 127 Gallon
15 Pressure minimum 100 kPa 15 PSI
16 Pressure maximum 220 kPa 32 PSI
ElectricalMetricImperial
17 Unit phase Ø voltage 3Ø 230/400VAC 3Ø 230/400VAC
18 Unit power consumption 2200 2200
19 Wetted parts Glasfiber reinforced Noryl Glasfiber reinforced Noryl
20 Pump phase Ø voltage 3Ø 230/400VAC 3Ø 230/400VAC
21 Pump motor 50Hz 2200 Watt 3.0 hp
22 Pump head 50Hz 19 Meter 62 ft
23 Pump pressure setting Manual Manual
24 Control No control No control
ConnectionsMetricImperial
25 Water inlet G 2" pump suction connection G 2" pump suction connection
26 Water outlet R 1", outer thread connection R 1", outer thread connection
27 Gas inlet 10 mm push to connect fitting 10 mm push to connect fitting
Dimensions & weightMetricImperial
28 Dim. (w) x (d) x (h) 420 x 665 x 1010 mm 16.5 x 26.2 x 39.8 inch
29 weight 33.6 Kg 74.1 lbs.
Remarks
30 Other remarks
  • Install and use the product only at an altitude less than 2000 meter

  • Enable charged operation of 0.5 meters below sea level, never more than 3 meters.

  • Install a foot valve on the intake pipe when the pump is located above sea level

  • Acoustic level of the pump is less than 70dBA

  • Use 4G1mm cable to connect the 3-phase pump, cable type H07RN-F

Back to: Turbiti Skid